Verification

Vendor, serial, hardware version

./fs_xgspon_mod.py telnet SMBSXXXXXXXX

Where SMBSXXXXXXXX is the livebox serial

then

/s/m/show 256
/s/m/show 257

These two commands should make it possible to display the serial, vendor and hardware version to verify the correct values ​​(in hex).

Reg status

/traffic/pon/show onu

————————- ONU INFO ————————–

Onu id 26

sdThreshold: 0

sfThreshold: 0

TO1: 80000

TO2: 1

eqd: XXXXXXXX

Serial Number(vendor code): SMBS

Serial Number(sn): XXXXXXX

Password: XX XX XX XX XX XX XX XX XX XX

Registration ID: 0xXXXXXXXXXXXXXXXX0000000000000000000000000000000000000000000000000000000000

————————- INFO END ————————–

Status O5

/traffic/pon/show link

—————– LINK STATE —————–

Operation State Machine: OPERATION (O5)

—————– STATE END —————–

VLAN

/system/mib/show 506

EntityID = 0x0101

OuterPriFilter = 15

OuterVidFilter = 4096

OuterTPIDFilter = 0

InnerPriFilter = 8

InnerVidFilter = 832

InnerTPIDFilter = 5

EtherTypeFilter = 0

AniBriPortNum = 2

RmTagTreat = 1

OuterPriTreat = 15

OuterVidTreat = 0

OuterTPIDTreat = 0

InnerPriTreat = 8

InnerVidTreat = 2800

InnerTPIDTreat = 2

EntityID = 0x0101

OuterPriFilter = 15

OuterVidFilter = 4096

OuterTPIDFilter = 0

InnerPriFilter = 8

InnerVidFilter = 835

InnerTPIDFilter = 5

EtherTypeFilter = 0

AniBriPortNum = 6

RmTagTreat = 1

OuterPriTreat = 15

OuterVidTreat = 0

OuterTPIDTreat = 0

InnerPriTreat = 8

InnerVidTreat = 835

InnerTPIDTreat = 2

VLAN Mapping

/traffic/eth/show connect all

US BRIDGE 65535


INDEX = 0, SLOT = 1, PORT = 4, VLANFILTER = 832 PRIFILTER = 0x1

VLAN MATCH : MATCH

VLAN ACT   : REPLACE

OUT  VID   : 2800

OUT  PRI   : 0

TCI MAPPING:

            * PRI 0  -> FLOW 1

            * PRI 1  -> FLOW 0

            * PRI 2  -> FLOW 0

            * PRI 3  -> FLOW 0

            * PRI 4  -> FLOW 0

            * PRI 5  -> FLOW 0

            * PRI 6  -> FLOW 0

            * PRI 7  -> FLOW 0